The Type 8055 Full-Bore Magflowmeter is designed for filling and dosing operations, including data registration. The Type 8055 (continuous or batch control) finds use in sanitary processes, pharmaceuticals manufacturing and water treatment applications. It is also used in CIP and SIP applications. Combined with a valve as the actuating element, the Type 8055 accurately controls precision dosing and filling operations. The unit incorporates two transistor outputs (40VDC, 100mA), 0/4-20mA current output and RS485. The transistor outputs are each freely programmable and can be configured as pure switching outputs for a valve, alarm and rough/fine dosage. In addition, they can be configured proportionately to flow rate/volumes as pulse output (1250 Hz max.). Incorporating a large, easy-to-read graphic display, the Type 8055 is programmed locally via three keypads or by PC. The Type 8055 is available in sanitary, low-flow and general-purpose configurations. Measuring range for the sanitary version is 8.83 cubic ft/h to 9,888 cubic ft/h; low-flow version is 66 gal/h to 3,302 gal/h; general-purpose version is 636 cubic ft/h to 9,888 cubic ft/h. Accuracy for all versions is ±0.2% of reading (for liquid velocity >3.28 ft/s), while repeatability is better than 0.1%. /t1>b>co>Burkert,/b> Irvine, CA 92614. 800-325-1405.rsphone>918003251405/rsphone>